Product Information
GI-739
Low-durometer thixotropic tin-cure RTV-2 brush-on silicone
Tin cure (condensation)
General Information
GI-739 is a thixotropic (resistant to flow) tin catalyzed silicone designed to be used when painting or spraying onto vertical surfaces. GI-739 does not contain the mold rotting thixo-additives widely used today, but offers the end user the same ease of use and detail reproducibility. When catalyzed with one of our library life extending catalysts (see supplemental products) and stored correctly, a longer life of the cured mold should be expected. Its high tear strength, elongation and tensile strength make it an excellent choice for any mold making application. It is also resistant to inhibition by most common mold making substrates, eliminating the need to use mold sealers.
Typical Properties
Uncatalyzed Compound
- Color
- Base:WhiteActivator:Teal
- Viscosity
- Base:500,000cpsActivator:1,000cps
- Mixing Ratio
- By weight:100:10By volume:100:11.1
- Mixed Viscosity
- 300,000–350,000cps
- Working Time
- 0.7–1.0hours
- Cure Time
- 16–18hours
- Shelf Life
- 6months
Vulcanized (Cured) Properties
Measured at 7 days, 70°F / 50% relative humidity
- Shore A Hardness
- One day:157 days:18±4 durometer
- Tear Resistance
- 70 ± 10ppiASTM D624
- Tensile Strength
- 275 ± 25psiASTM D412
- Elongation
- 500 ± 50%ASTM D412
- Service Temperature
- -60 to 350°F
- Shrinkage
- 0.10%
- Specific Gravity
- 1.10
- Coverage
- 25.2in³ / lb